HEALTHCARE APPLICATION

PLASMAIR for hospitals, clinics and ASSTs

Fully automatic 24/7 decontamination for critical healthcare environments. Designed for operating theatres, ISO-classified rooms, sterile preparation areas and controlled healthcare environments. Continuous environmental monitoring, ISO 14644-1:2022 compliance and validated bacterial load reduction above 95%.

Airborne multidrug‑resistant bacteria: MRSA, Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter baumannii, can survive in the air for hours. Traditional HEPA filters do not remove particles < 0.3 µm. Cold SDBD plasma does.

Traditional filtration captures contaminants.

PLASMAIR adds active microbial inactivation through cold SDBD plasma technology.

THE PROBLEM

Airborne pathogens in healthcare environments

Healthcare-associated infections (HAIs) remain one of the leading causes of hospital complications in Europe. Airborne microbial contamination is recognised as a major risk factor in operating theatres and controlled healthcare environments.

Airborne microorganisms may be transported through microparticles in the 0.1–0.5 μm range, one of the most difficult fractions for traditional mechanical filtration systems.

Multidrug-resistant bacteria — including MRSA, Klebsiella pneumoniae, Pseudomonas aeruginosa and Acinetobacter baumannii — represent a growing public health concern. These pathogens may survive for extended periods in air, on surfaces and within ventilation systems.

Mechanical filtration alone may not be sufficient in critical healthcare environments.

PLASMAIR integrates controlled cold SDBD plasma technology generating reactive oxygen and nitrogen species (ROS/RNS) for continuous microbial load reduction in air and on exposed surfaces. These reactive species contribute to microbial inactivation through oxidative stress mechanisms affecting bacterial cell membranes, proteins and viral surface structures.

During occupied daytime operation, the system maintains ozone concentrations within European exposure limits while continuously reducing microbial load.

HEALTHCARE-ASSOCIATED INFECTIONS (HAI) RISK OVERVIEW
BACTERIUM AND RISKINCIDENCE AND CONTEXT
Staphylococcus aureus (MRSA) - High ~30% surgical infections
Klebsiella pneumoniae - High ~10.4% HAI
Pseudomonas aeruginosa - High ~8.1% HAI
Acinetobacter baumannii - Critical Lethality 17–46%
Clostridioides difficile - High ~12% HAI
Aspergillus spp. (spores) - High Immunocompromised patients
Source: Istituto Superiore di Sanità, Epicentro, ECDC

TARGET ENVIRONMENTS

Where PLASMAIR works in healthcare

Each healthcare environment has specific characteristics and regulatory requirements. PLASMAIR is configured and calibrated for each setting.

Operating rooms and surgical suites

Critical surgical environments. Decontamination between procedures during surgical downtime. Reduction of bacterial load before every procedure.

ISO 5– ISO7 – ISO8 class

Nuclear medicine

Tightly confined environments that require continuous particulate and microbiological monitoring, and therefore daily, continuous decontamination.

Confined spaces

Obstetric and gynaecological theatres

Highly controlled contamination-sensitive environments

High-level contamination control

High-risk healthcare departments

Areas where strict environmental control is essential and contamination risk is high (e.g. hospital pharmacy, sterile cytotoxic compounding labs, packaging zones, research laboratories, etc.).

24/7 monitoring

TECHNICAL SPECIFICATIONS

PLASMAIR nameplate data

Performance
ParameterValue / Range
Bacterial load reduction> 95%
Particle reduction ≥ 0.5 µm~ 50%
F9 filter efficiencyEM ≥ 95% @ 0.1 µm
Ozone (Day cycle)Selectable 0–50 ppb b
Ozone (Night cycle)400–600 ppb up to 240 min
Air recirculation80% treated / 20% external
HVAC energy saving~ 40%
Regulatory complianceISO 14644-1:2022
System and installation
ParameterValue / Range
Installation typeDucted on existing HVAC
Structural modificationsNone
Sensor protocolRS485 Modbus
Monitored parametersCO₂, T, RH, ΔP
Local interfaceIntegrated touchscreen
Remote connectivityIoT cloud, web access
Patent protectionPoloPlasma Patent 2022
MaintenanceScheduled maintenance only

WHY CHOOSE PLASMAIR

System benefits

>95%

Microbiological decontamination

Reduction of bacteria, viruses, moulds and spores in air and on surfaces.
Validated through continuous 24/7 operation over 6 months.

−40%

Energy saving

Optimised recirculation reduces outdoor air volumes while maintaining ISO classification, reducing HVAC energy demand.

+100%

Filter lifetime

Plasma continuously decontaminates filters internally, extending their service life and reducing replacement frequency.

24/7

Continuous monitoring

All environmental parameters are continuously logged.
Historical data are available for ISO 14644-1:2022 audits and validation reports.

Zero

Seamless integration

Installed on the existing  airflow lines, at the selected point. No structural changes to the environment.

2022

Patented technology

Protected by PoloPlasma patent technology.

STANDARDS AND COMPLIANCE

UNI EN ISO 14644-1:2022

The UNI EN ISO 14644‑1:2022 standard, in force since 2022, has updated and tightened requirements for cleanrooms and controlled environments in healthcare. PLASMAIR has been designed to meet, and exceed, all required parameters.

The standard defines air cleanliness classes based on particle concentration per cubic metre. Operating theatres generally require class ISO 5 (above the surgical field) and ISO 7/8 (for the room).

Multidrug‑resistant bacteria, MRSA, Klebsiella, Pseudomonas, Acinetobacter, are now a major public health emergency. They survive on surfaces and in the air for hours, days, weeks. Cleaning and mechanical filtration alone are not sufficient.

PLASMAIR acts where traditional systems stop: it generates reactive oxygen and nitrogen species (ROS/RNS) that, through oxidative stress mechanisms, inactivate bacterial cell membranes and viral receptors at ozone concentrations that are safe for staff.

Classe

ISO Class 5

Surgical field. Max 3,520 particles/m³ ≥ 0.5 µm. Highest standard.

Classe

ISO Class 7

General operating theatre. Max 352,000 particles/m³ ≥ 0.5 µm.

ISO 14644-1 Compliance Overview
REQUIRED PARAMETERISO REQUIREMENTPLASMAIR
Microparticle count ISO Class 5-7/8 ✓ Exceeds ISO requirements
Microbiological contaminants Active monitoring ✓ 24/7 monitored
Filtration efficiency F9 min. (EM ≥ 95%) ✓ F9 + SDBD plasma
Integrated differential pressure sensor Continuous control ✓ Dedicated sensor
Temperature and humidity Mandatory recording ✓ Integrated datalogger
CO₂ – air quality Monitoring ✓ Integrated sensor
Audit documentation Historical log required ✓ Cloud-based data logging

OPERATING MODES

Dual automatic operating modes

PlASMAIR automatically switches between occupied daytime operation and unoccupied intensive decontamination cycles

Daytime — with personnel

Normal decontamination

Target ozone

0-50 ppb

EU ozone health threshold

120 µg/m³ — ≤ 50 ppb (below EU health threshold)

Plasma action

Modulated, continuous

F9 filtration

Active 24/7

O₃ sensors

Redundant, automatic alarm

Result

ISO air quality maintenance

Night — without personnel

Intensive decontamination

Target ozone

400-600 ppb up to 240 min

Action

High-concentration plasma, air and surfaces

Safety

Presence sensors + door lock

Alarms

Visual and acoustic active

End of cycle

Automatic O₃ reduction

Result

Deep decontamination

OPERATING MODES

Ce.Me.Di. Turin tests — real‑world results

Ce.Me.Di.

Turin Standard operating room

ParameterBeforeAfterResult
Bacterial load (CFU)69<10−85%
Particles 0.5 µm/m³100,000<20,000−80%
ISO Classifica-tionNon classified /ISO10ISO7 range✓ISO7 achieved

Validation protocol

PlASMAIR automatically switches between occupied daytime operation and unoccupied intensive decontamination cycles

ECONOMIC BENEFITS

Return on investment for hospital management

−85%

Microbiological load

Fewer HAI means fewer prolonged antibiotic therapies, fewer rehospitalisations and fewer post‑operative complications.

−40%

HVAC energy saving

Optimised 80/20 recirculation reduces outdoor air volumes and thermal loads, lowering system energy consumption.

+100%

Filter life

Plasma decontaminates filters from within, extending useful life and reducing replacement frequency and cost.

Zero

Routine intervention

Fully automatic system with remote monitoring. Technical staff intervene only for scheduled maintenance.

SAFETY

Active staff protection

Redundant O₃ sensors

Two independent ozone sensors continuously monitor ozone concentration.
Independent cross-check monitoring validates sensor readings in real time and enhances operational safety.
Automatic alarms are activated if the safety threshold is exceeded.

Alarm threshold: 60 ppb/m³

Presence sensors and door contacts

Detection of a person or door opening during the intensive cycle immediately stops the system and activates alarms.

Instant automatic shutdown

Visual and acoustic alarms

Light and sound signalling inside and outside the room during the intensive cycle.

“Accidental entry is actively prevented.”

Multimodal signalling

Automatic O₃ removal

At the end of the intensive cycle, the system automatically reduces ozone concentration before staff return.

Accidental entry is actively prevented.

Emergency access PPE

On request, we supply certified A1P2 gas masks for staff who may need to access the area in an emergency.

EN 140 · EN 143 · CE 2834

Ozone regulatory compliance

Daytime cycle is well below the EU threshold. Night‑time cycle is limited to unoccupied spaces with active physical and safety barriers.

EU 2008/50/EC compliant

Ready to protect your critical environment?

Request a technical assessment of your HVAC infrastructure and contamination-control requirements. Our engineering team will evaluate the integration of PLASMAir technology within your existing ventilation systems.